5950-01-209-9555 TRANSFORMER,POWER Index 6150-01-209-9557 CABLE ASSEMBLY,SPECIAL PURPOSE,E

National Stock Number:
5955-01-209-9556

Federal Supply Class:
5955

National Item Identification Number:
012099556

Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
CR79/U16M7772181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-3098/6381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-3098/6381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DRIVE LEVEL RATING4.0 MILLIWATTS MINIMUM AND 6.0 MILLIWATTS MAXIMUM
BODY LENGTH0.530 INCHES MAXIMUM
BODY THICKNESS0.150 INCHES MAXIMUM
BODY WIDTH0.402 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.184 INCHES MINIMUM AND 0.200 INCHES MAXIMUM
CIRCUIT RESONANCESERIES RESONANCE
EQUIVALENT RESISTANCE VALUE IN OHMS20.0 MAXIMUM
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.005 TO 0.005
OPERATING TEMP RANGE-55.0 TO 105.0 CELSIUS
OVERALL LENGTH0.753 INCHES MINIMUM AND 0.778 INCHES MAXIMUM
OVERALL THICKNESS0.183 INCHES MAXIMUM
OVERALL WIDTH0.435 INCHES MAXIMUM
MODE OF OSCILLATIONFUNDAMENTAL
SHUNT CAPACITANCE IN PICOFARADS7.0 MAXIMUM
SPECIFICATION/STANDARD DATA81349-MIL-C-3098/63 GOVERNMENT SPECIFICATION
SPECIFIED FREQUENCY16.777216 MEGAHERTZ
STYLE DESIGNATOROVAL BODY, PIN TERMINALS
TERMINAL DIAMETER0.038 INCHES MINIMUM AND 0.042 INCHES MAXIMUM
TERMINAL LENGTH0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MIL-C-3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).