5950-00-660-9504 TRANSFORMER,POWER Index 5955-00-660-9508 CRYSTAL UNIT,QUARTZ

National Stock Number:
5955-00-660-9507

Federal Supply Class:
5955

National Item Identification Number:
006609507

Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
290-7942-0013499ROCKWELL COLLINS, INC.
290-7942-00M2000136MICROSEMI CORP. - HIGH PERFORMANCE TIMING
CR129/U9M46300081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-3098/11081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-3098/11081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DRIVE LEVEL RATING4.0 MILLIWATTS MINIMUM AND 6.0 MILLIWATTS MAXIMUM
BODY WIDTH0.402 INCHES MAXIMUM
BODY THICKNESS0.150 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.184 INCHES MINIMUM AND 0.200 INCHES MAXIMUM
CIRCUIT RESONANCEANTIRESONANCE
EQUIVALENT RESISTANCE VALUE IN OHMS35.0 MAXIMUM
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.0035 TO 0.0035 AND -0.005 TO 0.005 AND -0.002 TO 0.002
LOAD CAPACITANCE IN PICOFARADS31.5 MINIMUM AND 32.5 MAXIMUM
OPERATING TEMP RANGE-55.0 TO 90.0 CELSIUS
OVERALL LENGTH0.530 INCHES MAXIMUM
OVERALL THICKNESS0.183 INCHES MAXIMUM
OVERALL WIDTH0.435 INCHES MAXIMUM
MATERIALGLASS COVER, HOLDER
MODE OF OSCILLATIONFUNDAMENTAL
SHUNT CAPACITANCE IN PICOFARADS7.0 MAXIMUM
SPECIFICATION/STANDARD DATA81349-MIL-C-3098/110 GOVERNMENT SPECIFICATION
SPECIFIED FREQUENCY9.9463 MEGAHERTZ
STYLE DESIGNATORRECTANGULAR BODY, GULL WING
TERMINAL LENGTH0.5003 INCHES MINIMUM
TERMINAL DIAMETER0.015 INCHES MINIMUM AND 0.019 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MIL-C-3098/38 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).


Click here to Register for Free 30-day Trial