Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
120-000-001-555901DARE ELECTRONICS, INC.
CR-82/U103.854700MHZ81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CR82/U103M854781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CR82U00809WENZEL INTERNATIONAL INC
MIL-PRF-3098/5981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC3098-5981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DRIVE LEVEL RATING1.6 MILLIWATTS MINIMUM AND 2.4 MILLIWATTS MAXIMUM
BODY LENGTH0.530 INCHES MAXIMUM
BODY WIDTH0.402 INCHES MAXIMUM
BODY THICKNESS0.150 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.184 INCHES MINIMUM AND 0.200 INCHES MAXIMUM
CIRCUIT RESONANCESERIES RESONANCE
EQUIVALENT RESISTANCE VALUE IN OHMS60.0 NOMINAL
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.005 TO 0.005
OVERALL LENGTH0.778 INCHES MAXIMUM
OVERALL THICKNESS0.183 INCHES MAXIMUM
OVERALL WIDTH0.435 INCHES MAXIMUM
MODE OF OSCILLATIONFIFTH OVERTONE
OPERATING TEMP RANGE-55.0 TO 105.0 CELSIUS
SHUNT CAPACITANCE IN PICOFARADS7.0 MAXIMUM
SPECIFIED FREQUENCY103.8547 MEGAHERTZ
STYLE DESIGNATOROVAL BODY, PIN TERMINALS
TERMINAL DIAMETER0.038 INCHES MINIMUM AND 0.042 INCHES MAXIMUM
TERMINAL LENGTH0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MILC3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).