5955-00-137-5537 CRYSTAL UNIT,QUARTZ Index 5998-00-137-5548 CIRCUIT CARD ASSEMBLY

National Stock Number:
5955-00-137-5545

Federal Supply Class:
5955

National Item Identification Number:
001375545

Description:
CRYSTAL UNIT,QUARTZ

Detail:
An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.


Manufacturer Information:
418595-696214RAYTHEON COMPANY
CR19/U5M00000081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-3098/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-3098/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DRIVE LEVEL RATING8.0 MILLIWATTS MINIMUM AND 12.0 MILLIWATTS MAXIMUM
BODY LENGTH0.775 INCHES MAXIMUM
BODY THICKNESS0.317 INCHES MAXIMUM
BODY WIDTH0.725 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS0.478 INCHES MINIMUM AND 0.494 INCHES MAXIMUM
CIRCUIT RESONANCESERIES RESONANCE
EQUIVALENT RESISTANCE VALUE IN OHMS37.0 MAXIMUM
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT-0.005 TO 0.005
OPERATING TEMP RANGE-55.0 TO 105.0 CELSIUS
OVERALL LENGTH0.998 INCHES MINIMUM AND 1.023 INCHES MAXIMUM
OVERALL THICKNESS0.352 INCHES MAXIMUM
OVERALL WIDTH0.757 INCHES MAXIMUM
MODE OF OSCILLATIONFUNDAMENTAL
SHUNT CAPACITANCE IN PICOFARADS7.0 MAXIMUM
SPECIFICATION/STANDARD DATA81349-MIL-C-3098/4 GOVERNMENT SPECIFICATION
SPECIFIED FREQUENCY5.000 MEGAHERTZ
STYLE DESIGNATOROVAL BODY, PIN TERMINALS
TERMINAL LENGTH0.223 INCHES MINIMUM AND 0.248 INCHES MAXIMUM
TERMINAL DIAMETER0.048 INCHES MINIMUM AND 0.052 INCHES MAXIMUM
TEST DATA DOCUMENT81349-MIL-C-3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).