5930-01-350-3698 SWITCH,PUSH Index 5950-01-350-3700 COIL,RADIO FREQUENCY

National Stock Number:
5950-01-350-3699

Federal Supply Class:
5950

National Item Identification Number:
013503699

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
M L-C-39010/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39010/06-BR22KR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39010/06BR22KR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39010/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH0.365 INCHES MINIMUM AND 0.385 INCHES MAXIMUM
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS0.055 SINGLE COMPONENT SINGLE WINDING
FEATURES PROVIDEDTINNED WIRE LEADS
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING0.22 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
OVERALL DIAMETER0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM
MAXIMUM OPERATING TEMP125.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
QUALITY FACTOR50 MINIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RELIABILITY INDICATORESTABLISHED
WINDING OPERATING CURRENT1810.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING
SPECIFICATION/STANDARD DATA81349-MIL-C-39010/6 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39010 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).