5950-01-344-7581 REACTOR Index 5950-01-344-7583 REACTOR

National Stock Number:
5950-01-344-7582

Federal Supply Class:
5950

National Item Identification Number:
013447582

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
1515053854MAGNESPEC INC
8517981-107187HONEYWELL INTERNATIONAL INC.
C1546772149ELECTRONIC TRANSFORMER CORP


Techincal Specification:
BODY LENGTH0.820 INCHES MAXIMUM
DC RESISTANCE RATING IN OHMS0.015 SINGLE COMPONENT 1ST WINDING
DC RESISTANCE RATING IN OHMS0.015 SINGLE COMPONENT 2ND WINDING
DC RESISTANCE RATING IN OHMS0.400 SINGLE COMPONENT 3RD WINDING
DC RESISTANCE RATING IN OHMS0.400 SINGLE COMPONENT 4TH WINDING
DC RESISTANCE RATING IN OHMS0.400 SINGLE COMPONENT 5TH WINDING
DC RESISTANCE RATING IN OHMS0.400 SINGLE COMPONENT 6TH WINDING
FREQUENCY RATING15.75 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE TYPEFIXED
OVERALL DIAMETER1.445 INCHES MAXIMUM
MAXIMUM OPERATING TEMP170.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.112 INCHES SINGLE GROUP
RATING METHODELECTRICAL AND WINDING TURNS SINGLE COMPONENT ALL WINDING
RELIABILITY INDICATORNOT ESTABLISHED
TURN QUANTITY17 SINGLE COMPONENT 1ST WINDING
TURN QUANTITY17 SINGLE COMPONENT 2ND WINDING
TURN QUANTITY51 SINGLE COMPONENT 3RD WINDING
TURN QUANTITY51 SINGLE COMPONENT 4TH WINDING
TURN QUANTITY51 SINGLE COMPONENT 5TH WINDING
TURN QUANTITY51 SINGLE COMPONENT 6TH WINDING
WINDING CONDUCTOR SIZE0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 3RD WINDING
WINDING CONDUCTOR SIZE0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 4TH WINDING
WINDING CONDUCTOR SIZE0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 5TH WINDING
WINDING CONDUCTOR SIZE0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 6TH WINDING
WINDING CONDUCTOR SIZE0.05082 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 1ST WINDING
WINDING CONDUCTOR SIZE0.05082 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 2ND WINDING
WINDING OPERATING CURRENT12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING
WINDING OPERATING CURRENT12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING
WINDING OPERATING CURRENT600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH WINDING
WINDING OPERATING CURRENT600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 5TH WINDING
WINDING OPERATING CURRENT600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 6TH WINDING
WINDING OPERATING CURRENT600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD WINDING
WINDING QUANTITY6 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY12 WIRE LEAD
TEST DATA DOCUMENT07187-8517981 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial