5950-01-260-5288 COIL,ELECTRICAL Index 6150-01-260-5290 CABLE ASSEMBLY,POWER,ELECTRICAL

National Stock Number:
5950-01-260-5289

Federal Supply Class:
5950

National Item Identification Number:
012605289

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
2685307388TOROTEL, INC.
8064723B150RAYTHEON COMPANY
80647249956RAYTHEON COMPANY
80647254X10RAYTHEON COMPANY
917AS643030003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BODY HEIGHT1.320 INCHES MAXIMUM
BODY LENGTH3.250 INCHES MAXIMUM
BODY WIDTH2.450 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.640 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL LENGTH3.470 INCHES MAXIMUM
MAXIMUM OPERATING TEMP155.0 CELSIUS
MAXIMUM TRANSFORMER POWER RATING362.6 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT4.6 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT4.8 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE20.60 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE20.60 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE113.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE26.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE26.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING13.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING13.8 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING163.9 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING171.1 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
TERMINAL TYPE AND QUANTITY16 TURRET
THREAD SERIES DESIGNATORUNC SINGLE GROUP
TRANSFORMER WINDING CONNECTION TYPEWYE-WYE