5950-01-219-1342 TRANSFORMER,POWER Index 5950-01-219-1344 TRANSFORMER,POWER

National Stock Number:
5950-01-219-1343

Federal Supply Class:
5950

National Item Identification Number:
012191343

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1273-26340SMN2ITW GSE INC.
1273-263412867GSE HOLDINGS INC.


Techincal Specification:
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.312 INCHES NOMINAL
OVERALL LENGTH2.500 INCHES NOMINAL
OVERALL WIDTH3.000 INCHES NOMINAL
MAXIMUM TRANSFORMER POWER RATING48.0 VOLT-AMPERE SINGLE COMPONENT
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS MINIMUM AND 230.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE12.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL SECONDARY