5950-01-213-6445 COIL,RADIO FREQUENCY Index 5950-01-213-6447 TRANSFORMER,POWER

National Stock Number:
5950-01-213-6446

Federal Supply Class:
5950

National Item Identification Number:
012136446

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
166747-1193B150RAYTHEON COMPANY
166747-11949956RAYTHEON COMPANY
166747-11954X10RAYTHEON COMPANY
2904831-11910001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
498828-11900204TRANSCON TECHNOLOGIES, LLC
498828-1193B150RAYTHEON COMPANY
498828-11949956RAYTHEON COMPANY
498828-11954X10RAYTHEON COMPANY


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY OUTSIDE DIAMETER0.230 INCHES MAXIMUM
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
FEATURES PROVIDEDTINNED WIRE LEADS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONMOISTURE RESISTANT AND SALT SPRAY RESISTANT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING11.50 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM OPERATING TEMP125.0 DEG CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
OVERALL LENGTH0.340 INCHES MAXIMUM
QUALITY FACTOR30 MINIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT150.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT49956-498828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)