5950-01-208-4782 REACTOR Index 5950-01-208-4784 TRANSFORMER,POWER

National Stock Number:
5950-01-208-4783

Federal Supply Class:
5950

National Item Identification Number:
012084783

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
78342073030HAMILTON SUNDSTRAND CORPORATION
NH78342016236DLA LAND AND MARITIME DBA ENGINEERING AND TECHNICAL SUPPORT DIV DOCUMENT STANDARDIZATION DIVISION (VENDOR ITEM DRAWINGS)


Techincal Specification:
CRITICALITY CODE JUSTIFICATIONFEAT
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.740 INCHES MINIMUM AND 1.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT1.250 INCHES MAXIMUM
OVERALL LENGTH2.080 INCHES MAXIMUM
OVERALL WIDTH1.480 INCHES MINIMUM AND 1.560 INCHES MAXIMUM
MAXIMUM OPERATING TEMP170.0 CELSIUS
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING HOLE DIAMETER0.140 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESNUCLEAR HARDNESS CRITICAL ITEM
WINDING OPERATING CURRENT12.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT48.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE353.00 AC VOLTS MINIMUM AND 430.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING5.16 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING5.52 VOLTS-AMPERES SINGLE COMPONENT ALL SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY9 WIRE LOOP


Click here to Register for Free 30-day Trial