5950-01-208-3593 TRANSFORMER,RADIO FREQUENCY Index 5950-01-208-3595 COIL,RADIO FREQUENCY

National Stock Number:
5950-01-208-3594

Federal Supply Class:
5950

National Item Identification Number:
012083594

Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
06365-3832997BOURNS INC
06365-3876493BELL INDUSTRIES INC J W MILLER MAGNETICS DIV
558-7107-38-00071279INTERCONNECTION PRODUCTS INC
7107-3871279INTERCONNECTION PRODUCTS INC
898481564ARTTED CO INC
L11-0004-03814304L3HARRIS TECHNOLOGIES, INC.


Techincal Specification:
ADJUSTMENT DEVICE DRIVE TYPESLOTTED SCREW SINGLE COMPONENT
ADJUSTMENT METHOD AND QUANTITY1 ADJUSTABLE CORE SINGLE COMPONENT
BODY HEIGHT0.465 INCHES MINIMUM AND 0.495 INCHES MAXIMUM
BODY LENGTH0.395 INCHES MINIMUM AND 0.405 INCHES MAXIMUM
BODY WIDTH0.395 INCHES MINIMUM AND 0.405 INCHES MAXIMUM
COIL FORM TYPEHOLLOW SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS9.300 SINGLE COMPONENT SINGLE WINDING
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.395 INCHES MINIMUM AND 0.405 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING108.00 MICROHENRIES MINIMUM AND 132.00 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE WINDING
MAXIMUM OPERATING TEMP105.0 CELSIUS
MOUNTING METHODTAB SINGLE GROUP
MOUNTING TAB WIDTH0.047 INCHES MINIMUM AND 0.053 INCHES MAXIMUM
QUALITY FACTOR47 MINIMUM AND 50 MAXIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT165.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
TERMINAL TYPE AND QUANTITY2 PIN


Click here to Register for Free 30-day Trial