REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
850069507187HONEYWELL INTERNATIONAL INC.
K-23609798PAYNE MAGNETICS, INC.
PR-K-23609798PAYNE MAGNETICS, INC.


Techincal Specification:
BODY HEIGHT0.470 INCHES MAXIMUM
BODY LENGTH0.450 INCHES NOMINAL
BODY WIDTH0.300 INCHES NOMINAL
DC RESISTANCE RATING IN OHMS0.110 SINGLE COMPONENT 3RD WINDING
DC RESISTANCE RATING IN OHMS0.110 SINGLE COMPONENT 2ND WINDING
DC RESISTANCE RATING IN OHMS0.250 SINGLE COMPONENT 1ST WINDING
DC RESISTANCE RATING IN OHMS0.250 SINGLE COMPONENT 4TH WINDING
FREQUENCY RATING100.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING100.00 MICROHENRIES MINIMUM SINGLE COMPONENT 1ST WINDING
INDUCTANCE RATING100.00 MICROHENRIES MINIMUM SINGLE COMPONENT 4TH WINDING
INDUCTANCE RATING30.00 MICROHENRIES MINIMUM SINGLE COMPONENT 2ND WINDING
INDUCTANCE RATING30.00 MICROHENRIES MINIMUM SINGLE COMPONENT 3RD WINDING
INDUCTANCE TYPESWINGING
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT ALL WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT250.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT ALL WINDING
WINDING QUANTITY4 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY8 PIN