5950-01-199-7225 TRANSFORMER,POWER Index 6210-01-199-7227 FIXTURE,LIGHTING

National Stock Number:
5950-01-199-7226

Federal Supply Class:
5950

National Item Identification Number:
011997226

Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
9T92A10G208929ALLEN TOOL PHOENIX, INC
9T92A10G208931GENERAL ELECTRIC CO MEDIUM TRANSFORMER DEPT


Techincal Specification:
ADJUSTMENT DEVICE DRIVE TYPESHAFT SINGLE COMPONENT
ADJUSTMENT METHOD AND QUANTITY1 ADJUSTABLE CONTROL SINGLE COMPONENT
BODY LENGTH5.625 INCHES MAXIMUM
BODY WIDTH5.188 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEPARTIALLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPTWO PHASE TO TWO PHASE SINGLE COMPONENT
OVERALL HEIGHT6.062 INCHES NOMINAL
MAXIMUM OPERATING TEMP105.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.312 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT
WINDING OPERATING CURRENT14.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE0.00 AC VOLTS MINIMUM AND 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING POWER RATING1.74 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT
TERMINAL TYPE AND QUANTITY1 TERMINAL BLOCK W/SCREWS


Click here to Register for Free 30-day Trial