5950-01-165-5351 REACTOR Index 5950-01-165-5353 REACTOR

National Stock Number:
5950-01-165-5352

Federal Supply Class:
5950

National Item Identification Number:
011655352

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
438250-0307690BAE SYSTEMS CONTROLS INC
BLF-96715634MAGNETIKA INC
BLF-96780223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC


Techincal Specification:
BODY LENGTH0.563 INCHES NOMINAL
BODY OUTSIDE DIAMETER1.188 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE0.600 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE BASE OF AN ISOSCELES TRIANGLE0.300 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
DC RESISTANCE RATING IN OHMS0.130 SINGLE COMPONENT SINGLE WINDING
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING320.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
INDUCTANCE TYPEFIXED
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY3 SINGLE GROUP
MOUNTING HOLE DIAMETER0.073 INCHES NOMINAL AND 0.156 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT2.5 AMPERES DC MINIMUM AND 3.7 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY2 PIN