5950-01-157-7758 TRANSFORMER,POWER Index 5950-01-157-7760 TRANSFORMER,POWER

National Stock Number:
5950-01-157-7759

Federal Supply Class:
5950

National Item Identification Number:
011577759

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1204-00-003223338WAVETEK U S INC DIV OF WAVETEK CORP
178-003223338WAVETEK U S INC DIV OF WAVETEK CORP


Techincal Specification:
BODY HEIGHT2.800 INCHES NOMINAL
BODY LENGTH3.750 INCHES NOMINAL
BODY WIDTH3.120 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.218 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT0.6 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT1.0 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT1.2 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT6.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE120.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE100.00 AC VOLTS NOMINAL AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE6.70 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE33.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE36.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE8.10 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY15 WIRE LEAD