CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.730 INCHES MINIMUM AND 6.770 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.150 INCHES MINIMUM AND 4.170 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
INCLOSURE TYPE | PARTIALLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
OVERALL HEIGHT | 9.700 INCHES MAXIMUM |
OVERALL LENGTH | 7.500 INCHES MAXIMUM |
OVERALL WIDTH | 6.750 INCHES MAXIMUM |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING METHOD | SLOT SINGLE GROUP |
MOUNTING SLOT WIDTH | 0.280 INCHES NOMINAL SINGLE GROUP |
PART NAME ASSIGNED BY CONTROLLING AGENCY | T-1 TRANSFORMER |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 7.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL AND 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 450.00 AC VOLTS NOMINAL AND 500.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING POWER RATING | 3.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |