5950-01-064-4789 REACTOR Index 5950-01-064-4791 TRANSFORMER,POWER

National Stock Number:
5950-01-064-4790

Federal Supply Class:
5950

National Item Identification Number:
010644790

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
9100-30391LQK8KEYSIGHT TECHNOLOGIES, INC.
9100-303928480HEWLETT-PACKARD COMPANY
9100-30397ZXR5KEYSIGHT TECHNOLOGIES INC
PX-392005216PHOENIX TRANSFORMER CO


Techincal Specification:
BODY HEIGHT1.870 INCHES NOMINAL
BODY LENGTH2.250 INCHES NOMINAL
BODY WIDTH2.200 INCHES MAXIMUM
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING48.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING HOLE DIAMETER0.132 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE TERMINAL OF SECONDARY WINDING NO. 2 IS CONNECTED TO CENTER @TAP OF SECONDARY WINDING NO. 1
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.2 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT250.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE120.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY
WINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL AND 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY
WINDING OPERATING VOLTAGE20.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE9.10 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY9 WIRE LEAD