Description:
COIL,RADIO FREQUENCY

Detail:
An item consisting of a partial turn as one or more turns of wire or other conductive material which constitutes one continuous untapped winding. It may be wound or formed in other than a circular manner and may be self-supporting, requiring no coil form. It is specifically designed to furnish inductive reactance in a circuit carrying radio frequency current ranging from 20 kilohertz (kilocycles) and above. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). The coil has only two electrical terminals. For items having tapped winding or more than one winding - see TRANSFORMER, RADIO FREQUENCY. For coils wound on resistors, which are designed to be inserted in the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC.


Manufacturer Information:
212624-110106KW9LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
240-2715-73113499ROCKWELL COLLINS, INC.
LT10K26381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-1530581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-1530581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS75089-4796906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY LENGTH0.390 INCHES MINIMUM AND 0.430 INCHES MAXIMUM
COIL FORM TYPESOLID SINGLE COMPONENT
CORE CONSTRUCTIONS0LID SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS678.000 SINGLE COMPONENT SINGLE WINDING
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING100.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
OVERALL DIAMETER0.152 INCHES MINIMUM AND 0.172 INCHES MAXIMUM
MAXIMUM OPERATING TEMP105.0 CELSIUS
MOUNTING METHODTERMINAL SINGLE GROUP
QUALITY FACTOR18 MINIMUM SINGLE COMPONENT SINGLE WINDING
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESMAGNETICALLY SHIELDS
WINDING OPERATING CURRENT11.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE WINDING
SPECIFICATION/STANDARD DATA96906-MS75089 GOVERNMENT STANDARD
TERMINAL TYPE AND QUANTITY2 WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-15305 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).