5950-01-061-9806 TRANSFORMER,POWER Index 5950-01-061-9809 TRANSFORMER,RADIOFREQUENCY

National Stock Number:
5950-01-061-9807

Federal Supply Class:
5950

National Item Identification Number:
010619807

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1204-00-000523338WAVETEK U S INC DIV OF WAVETEK CORP


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.187 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FEATURES PROVIDEDCOLOR CODED LEAD
FREQUENCY RATING50.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT2.100 INCHES NOMINAL
OVERALL LENGTH2.630 INCHES NOMINAL
OVERALL WIDTH2.200 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.156 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT280.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS MINIMUM AND 125.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING VOLTAGE18.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE36.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE64.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODCORE GROUNDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY14 WIRE LEAD


Click here to Register for Free 30-day Trial