5950-01-057-3233 REACTOR Index 5950-01-057-3235 TRANSFORMER,POWER

National Stock Number:
5950-01-057-3234

Federal Supply Class:
5950

National Item Identification Number:
010573234

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
8584132-111447L3 TECHNOLOGIES, INC.
8584132-149671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES
XT 1343249671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES


Techincal Specification:
BODY HEIGHT2.120 INCHES MAXIMUM
BODY LENGTH2.380 INCHES NOMINAL
BODY WIDTH2.380 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
DC RESISTANCE RATING IN OHMS0.002 SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING2.5 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING60.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
INDUCTANCE TYPEFIXED
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.209 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT50.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG