5950-01-036-6136 TRANSFORMER,POWER Index 5950-01-036-6139 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5950-01-036-6137

Federal Supply Class:
5950

National Item Identification Number:
010366137

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
H-111W15634MAGNETIKA INC
H-111W80223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC
ME0190340000418876U S ARMY AVIATION AND MISSILE COMMAND


Techincal Specification:
BODY HEIGHT6.620 INCHES MINIMUM AND 6.813 INCHES MAXIMUM
BODY LENGTH4.940 INCHES MINIMUM AND 5.063 INCHES MAXIMUM
BODY WIDTH4.190 INCHES MINIMUM AND 4.310 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.010 INCHES MINIMUM AND 4.111 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.260 INCHES MINIMUM AND 3.360 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.250 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT200.0 MILLIAMPERES DC MAXIMUM AND 450.0 MILLIAMPERES DC MAXIMUM AND 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 210.00 AC VOLTS NOMINAL AND 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE450.00 AC VOLTS NOMINAL AND 1.20 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
TERMINAL TYPE AND QUANTITY10 TAB, SOLDER LUG
THREAD QUANTITY PER INCH20 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial