5950-01-036-0136 REACTOR Index 5950-01-036-0139 TRANSFORMER,POWER

National Stock Number:
5950-01-036-0138

Federal Supply Class:
5950

National Item Identification Number:
010360138

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1385423095C-COR ELECTRONICS INC
1462723095C-COR ELECTRONICS INC
9100-003233783BR COMMUNICATIONS INC
S-9100-003233783BR COMMUNICATIONS INC


Techincal Specification:
BODY HEIGHT5.000 INCHES NOMINAL
BODY LENGTH5.630 INCHES NOMINAL
BODY WIDTH4.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY 1ST CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.375 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY 1ST CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY 2ND CENTER GROUP
FEATURES PROVIDEDCOLOR CODED LEAD
FREQUENCY RATING47.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY8 ALL GROUPINGS
MOUNTING METHODTHREADED HOLE ALL GROUPINGS
NOMINAL THREAD SIZE0.190 INCHES ALL GROUPINGS
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESIPRIMARY; 5 SECONDARY WINDINGS
WINDING OPERATING CURRENT1.3 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT11.0 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT3.8 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS NOMINAL AND 117.00 AC VOLTS NOMINAL AND 220.00 AC VOLTS NOMINAL AND 240.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE18.00 DC VOLTS MINIMUM AND 22.00 DC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE18.00 DC VOLTS MINIMUM AND 22.00 DC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE4.50 DC VOLTS MINIMUM AND 6.50 DC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE9.00 DC VOLTS MINIMUM AND 11.00 DC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY16 WIRE LEAD
THREAD SERIES DESIGNATORUNF ALL GROUPINGS


Click here to Register for Free 30-day Trial