BODY HEIGHT | 5.940 INCHES MINIMUM AND 6.060 INCHES MAXIMUM |
BODY LENGTH | 7.940 INCHES MINIMUM AND 8.060 INCHES MAXIMUM |
BODY WIDTH | 3.690 INCHES MINIMUM AND 3.810 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
III MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
III TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA AND DELTA-WYE |
INCLOSURE TYPE | HERMETICALLY SEALED |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
PROPRIETARY CHARACTERISTICS | PACS |
MAXIMUM TRANSFORMER POWER RATING | 1.8 KILOVOLT-AMPERE SINGLE COMPONENT |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS,WITH FIFTH SECONDARY CENTER TAPPED |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 25.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING CURRENT | 25.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING CURRENT | 3.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING CURRENT | 3.0 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
WINDING OPERATING VOLTAGE | 120.00 AC VOLTS MINIMUM AND 208.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 17.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 17.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
WINDING OPERATING VOLTAGE | 34.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 34.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
WINDING POWER RATING | 51.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
WINDING POWER RATING | 51.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
WINDING POWER RATING | 862.5 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
WINDING POWER RATING | 862.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 18 TAB, SOLDER LUG |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |