5950-01-030-7762 TRANSFORMER,POWER Index 5950-01-030-7764 TRANSFORMER,POWER

National Stock Number:
5950-01-030-7763

Federal Supply Class:
5950

National Item Identification Number:
010307763

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
NES-491986632NEWTON ENGINEERING SERVICE INC


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FEATURES PROVIDEDCOLOR CODED LEAD
FREQUENCY RATING47.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT3.375 INCHES NOMINAL
OVERALL LENGTH2.875 INCHES NOMINAL
OVERALL WIDTH2.500 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE AND SLOT SINGLE GROUP
MOUNTING SLOT WIDTH0.156 INCHES NOMINAL SINGLE GROUP
SPECIAL FEATURES1PRIMARY WINDING; 5SECONDARY WINDINGS
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 5 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT10.0 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT1250.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT30.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE11.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE500.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY13 WIRE LEAD