5950-01-029-0851 TRANSFORMER,AUDIO FREQUENCY Index 5950-01-029-0853 TRANSFORMER,POWER

National Stock Number:
5950-01-029-0852

Federal Supply Class:
5950

National Item Identification Number:
010290852

Description:
COIL,ELECTRICAL

Detail:
An item generally consisting of one or more turns of wire or similar conductive material (in special cases it may be considered as a partial turn). It is specifically designed to concentrate magnetic flux generated by the flow of an electric current, to induce in itself an electromotive force, and to add or subtract inductive reactance in a circuit. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). For coils wound on resistors which are designed to be inserted into the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC..


Manufacturer Information:
053-2613-1A05954CELCO DBA CONSTANTINE ENGINEERING LABORATORIES CO
712908-105869RAYTHEON COMPANY
B2613-1A05954CELCO DBA CONSTANTINE ENGINEERING LABORATORIES CO


Techincal Specification:
BODY LENGTH4.380 INCHES MAXIMUM
BODY OUTSIDE DIAMETER4.180 INCHES MAXIMUM
CORE CONSTRUCTIONPOWDERED SINGLE COMPONENT
DC RESISTANCE RATING IN OHMS0.200 SINGLE COMPONENT 3RD WINDING
DC RESISTANCE RATING IN OHMS0.200 SINGLE COMPONENT 4TH WINDING
DC RESISTANCE RATING IN OHMS0.820 SINGLE COMPONENT 2ND TERTIARY
DC RESISTANCE RATING IN OHMS1.750 SINGLE COMPONENT 1ST WINDING
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING1.17 MILLIHENRIES NOMINAL SINGLE COMPONENT 1ST WINDING
INDUCTANCE RATING18.00 MICROHENRIES NOMINAL SINGLE COMPONENT 4TH WINDING
INDUCTANCE RATING17.00 MICROHENRIES NOMINAL SINGLE COMPONENT 3RD WINDING
INDUCTANCE RATING360.00 MICROHENRIES NOMINAL SINGLE COMPONENT 2ND WINDING
MOUNTING FACILITY QUANTITY3 SINGLE GROUP
MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT ALL WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT2.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING
WINDING OPERATING CURRENT1.34 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING
WINDING OPERATING CURRENT50.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 4TH WINDING
WINDING OPERATING VOLTAGE1.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL WINDING
WINDING OPERATING CURRENT850.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD WINDING
WINDING QUANTITY4 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY8 WIRE LEAD