BODY HEIGHT | 0.750 INCHES MAXIMUM |
BODY LENGTH | 1.800 INCHES MAXIMUM |
BODY WIDTH | 1.645 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.390 INCHES MINIMUM AND 1.410 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.190 INCHES MINIMUM AND 1.210 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION PROOF |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MAXIMUM OPERATING TEMP | 85.0 CELSIUS |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | EACH OUTPUT TERMINAL HAS AN EXTRA TAP; TERMINALS 16 THRU 27 ARE FOR HOOK UP WITH A THREE PHASE BRIDGE WHICH IS FOR TESTING PURPOSES |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
WINDING OPERATING CURRENT | 35.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
WINDING OPERATING CURRENT | 420.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING VOLTAGE | 12.50 DC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 10 TURRET |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |