CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.615 INCHES MINIMUM AND 5.635 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.865 INCHES MINIMUM AND 1.885 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
OVERALL HEIGHT | 7.070 INCHES MINIMUM AND 7.130 INCHES MAXIMUM |
OVERALL LENGTH | 7.410 INCHES MINIMUM AND 7.470 INCHES MAXIMUM |
OVERALL WIDTH | 2.870 INCHES MINIMUM AND 2.930 INCHES MAXIMUM |
MAXIMUM OPERATING TEMP | 130.0 CELSIUS |
MAXIMUM TRANSFORMER POWER RATING | 2100.0 WATTS SINGLE COMPONENT |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING HOLE DIAMETER | 0.214 INCHES MINIMUM AND 0.224 INCHES MAXIMUM SINGLE GROUP |
MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
RELIABILITY INDICATOR | NOT ESTABLISHED |
WINDING OPERATING CURRENT | 10.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
TERMINAL TYPE AND QUANTITY | 8 TURRET |
TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |