5950-01-019-6030 REACTOR Index 5950-01-019-6032 TRANSFORMER,POWER

National Stock Number:
5950-01-019-6031

Federal Supply Class:
5950

National Item Identification Number:
010196031

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
11240172149ELECTRONIC TRANSFORMER CORP
C74339204655GENERAL DYNAMICS MISSION SYSTEMS, INC.
SM-C-74339280063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT2.750 INCHES NOMINAL
BODY WIDTH3.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.250 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH6.625 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.750 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL LENGTH7.000 INCHES NOMINAL
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY4 ALL GROUPINGS
MOUNTING METHODBRACKET AND THREADED HOLE 1ST GROUP
MOUNTING METHODFLANGE AND SLOT 2ND GROUP
MOUNTING SLOT WIDTH0.187 INCHES NOMINAL 2ND GROUP
NOMINAL THREAD SIZE0.190 INCHES 1ST GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT11.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT22.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT6.0 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE21.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE37.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE37.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE3.00 AC VOLTS NOMINAL AND 57.00 AC VOLTS NOMINAL AND 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING407.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING814.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING POWER RATING126.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
TERMINAL TYPE AND QUANTITY14 PIN
THREAD SERIES DESIGNATORUNF 1ST GROUP


Click here to Register for Free 30-day Trial