5950-01-019-3760 REACTOR Index 5310-01-019-3762 WASHER,SHOULDERED

National Stock Number:
5950-01-019-3761

Federal Supply Class:
5950

National Item Identification Number:
010193761

Description:
REACTOR

Detail:
A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes SATURABLE REACTOR. For reactors with air cores, see COIL (as modified).


Manufacturer Information:
1705872964ROBERT M. HADLEY COMPANY, INC.
986143-282577RAYTHEON COMPANY
E403-209798PAYNE MAGNETICS, INC.


Techincal Specification:
BODY HEIGHT0.700 INCHES MAXIMUM
BODY LENGTH1.250 INCHES MAXIMUM
BODY WIDTH1.150 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.975 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
DC RESISTANCE RATING IN OHMS0.086 SINGLE COMPONENT SINGLE WINDING
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INDUCTANCE RATING300.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
INDUCTANCE TYPEFIXED
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.120 INCHES MINIMUM AND 0.130 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RATING METHODELECTRICAL SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT6.8 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY2 TURRET