TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
18B142904801L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC
18B1429-9004801L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC
30E3866PC404801L3HARRIS MARITIME POWER & ENERGY SOLUTIONS, INC


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS1.687 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.813 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BODY HEIGHT1.500 INCHES MAXIMUM
BODY WIDTH1.125 INCHES MAXIMUM
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS
MAXIMUM TRANSFORMER POWER RATING0.36 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING HOLE DIAMETER0.125 INCHES MINIMUM SINGLE GROUP AND 0.251 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
OVERALL LENGTH2.000 INCHES MINIMUM AND 2.126 INCHES MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT60.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT60.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE6.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY4 WIRE LEAD