5905-01-008-3107 RESISTOR,BOARD Index 5975-01-008-3109 LEAD,SLEEVE,SPREADE

National Stock Number:
5950-01-008-3108

Federal Supply Class:
5950

National Item Identification Number:
010083108

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
SM-C-743393-180063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
SMC74339304655GENERAL DYNAMICS MISSION SYSTEMS, INC.


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH6.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING1.0 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL LENGTH7.000 INCHES NOMINAL
OVERALL WIDTH3.500 INCHES NOMINAL
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.190 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT10.0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE17.95 AC VOLTS MINIMUM AND 19.05 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE27.00 AC VOLTS NOMINAL AND 33.00 AC VOLTS NOMINAL AND 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE53.35 AC VOLTS MINIMUM AND 56.65 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY10 SOLDER STUD
THREAD SERIES DESIGNATORUNF SINGLE GROUP