5950-00-995-1871 TRANSFORMER,POWER Index 5320-00-995-1874 RIVET,SOLID

National Stock Number:
5950-00-995-1872

Federal Supply Class:
5950

National Item Identification Number:
009951872

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
P304174042MERIT COIL AND TRANSFORMER CORP


Techincal Specification:
BODY HEIGHT2.500 INCHES NOMINAL
BODY LENGTH3.062 INCHES NOMINAL
BODY WIDTH2.125 INCHES NOMINAL
DISTANCE BETWEEN MOUNTING FACILITY CENTERS3.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING HOLE DIAMETER0.187 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT3.6 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
TERMINAL TYPE AND QUANTITY8 WIRE LEAD


Click here to Register for Free 30-day Trial