4460-00-723-3874 FILTER,AIR,ELECTROSTATIC Index 5995-00-723-3882 CABLE ASSEMBLY,RADIO FREQUENCY

National Stock Number:
5950-00-723-3881

Federal Supply Class:
5950

National Item Identification Number:
007233881

Description:
SATURABLE REACTOR

Detail:
AN ITEM WHOSE INDUCTANCE VALUE IS CONTROLLED BY ELECTRICAL MEANS. IT DEPENDS ON THE ACTION OF THE ELECTROMAGNET FLUX PRODUCED BY THE CONTROL WINDING UPON THE EFFECTIVE PERMEABILITY OF THE CORE. IT CONTAINS TWO OR MORE WINDINGS, AT LEAST ONE OF WHICH MUST BE A CONTROL WINDING. FOR ITEMS DESIGNED TO BE USED IN CONJUNCTION WITH A RECTIFIER(S) FOR AMPLIFICATION PURPOSES, SEE AMPLIFIER, MAGNETIC.


Manufacturer Information:
4030073386FREED TRANSFORMER CO
7165104454SENSOR SYSTEMS, L.L.C.


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
DC RESISTANCE RATING IN OHMS0.860 SINGLE COMPONENT SINGLE PRIMARY
DC RESISTANCE RATING IN OHMS10.000 SINGLE COMPONENT ALL CONTROL
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
OVERALL HEIGHT1.125 INCHES NOMINAL
OVERALL LENGTH4.750 INCHES NOMINAL
OVERALL WIDTH4.500 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING HOLE DIAMETER0.147 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SATURATION CURRENT RATING40.0 MILLIAMPERES
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 CONTROL SINGLE COMPONENT
WINDING OPERATING VOLTAGE33.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY6 TAB, SOLDER LUG