1005-00-722-9054 TRIGGER Index 5825-00-722-9063 INDICATOR,AZIMUTH

National Stock Number:
5950-00-722-9058

Federal Supply Class:
5950

National Item Identification Number:
007229058

Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
B848040REVDPCALL58474SUPERIOR ELECTRIC HOLDING GROUP LLC
H5478770G1PC1524446GENERAL ELECTRIC COMPANY


Techincal Specification:
BODY HEIGHT5.031 INCHES NOMINAL
BODY LENGTH7.281 INCHES NOMINAL
BODY WIDTH5.031 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH4.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRITICALITY CODE JUSTIFICATIONZZZY
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT6.812 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.312 INCHES SINGLE GROUP
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSMATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS
SPECIAL FEATURESTERMINALS 2 AND 3 JUMPERED TOGETHER EXTERNALLY
WINDING OPERATING CURRENT12.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE120.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE83.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
TERMINAL TYPE AND QUANTITY4 STANDOFF, THREADED STUD
THREAD QUANTITY PER INCH18 SINGLE GROUP
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial