5950-00-681-2045 TRANSFORMER,POWER Index 5950-00-681-2048 TRANSFORMER,POWER

National Stock Number:
5950-00-681-2046

Federal Supply Class:
5950

National Item Identification Number:
006812046

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
160184656232LOCKHEED MARTIN CORPORATION
224040210001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
27F1696256THORDARSON INC
292MS596P00104164RAYTHEON COMPANY
292MS596P0013B150RAYTHEON COMPANY
292MS596P00149956RAYTHEON COMPANY
292MS596P00154X10RAYTHEON COMPANY
3301704-299251MISSION SYSTEMS DAVENPORT INC.
598-401-1894210REVAPC2580064NAVAL SHIP SYSTEMS COMMAND
623L003PC722375FISCHER AND PORTER CO
G26185REVAPC2522375FISCHER AND PORTER CO
GT825HC126512NORTHROP GRUMMAN SYSTEMS CORPORATION
HS-43804386MAGNETEK INC HUNTINGTON DIV


Techincal Specification:
BODY HEIGHT2.750 INCHES MAXIMUM
BODY LENGTH1.938 INCHES MAXIMUM
BODY WIDTH1.812 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRITICALITY CODE JUSTIFICATIONFEAT
FREQUENCY RATING380.0 HERTZ MINIMUM AND 1.5 KILOHERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP131.0 FAHRENHEIT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWEAPONS SYSTEM ESSENTIAL
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING VOLTAGE150.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE24.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY7 SOLDER STUD
THREAD SERIES DESIGNATORUNC SINGLE GROUP