5950-00-648-6861 TRANSFORMER,POWER Index 5950-00-648-6863 TRANSFORMER,POWER

National Stock Number:
5950-00-648-6862

Federal Supply Class:
5950

National Item Identification Number:
006486862

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
1660080089EMERSON ELECTRIC CO WHITE-RODGERS DIV
1660097520BASLER ELECTRIC CO


Techincal Specification:
BODY HEIGHT3.730 INCHES NOMINAL
BODY LENGTH3.500 INCHES NOMINAL
BODY WIDTH2.850 INCHES NOMINAL
FREQUENCY RATING50.0 HERTZ NOMINAL OR 60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT70.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE600.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY10 TAB, SOLDER LUG