5996-00-648-2490 AMPLIFIER,MAGNETIC Index 5950-00-648-2497 TRANSFORMER,AUDIO FREQUENCY

National Stock Number:
5950-00-648-2491

Federal Supply Class:
5950

National Item Identification Number:
006482491

Description:
SATURABLE REACTOR

Detail:
AN ITEM WHOSE INDUCTANCE VALUE IS CONTROLLED BY ELECTRICAL MEANS. IT DEPENDS ON THE ACTION OF THE ELECTROMAGNET FLUX PRODUCED BY THE CONTROL WINDING UPON THE EFFECTIVE PERMEABILITY OF THE CORE. IT CONTAINS TWO OR MORE WINDINGS, AT LEAST ONE OF WHICH MUST BE A CONTROL WINDING. FOR ITEMS DESIGNED TO BE USED IN CONJUNCTION WITH A RECTIFIER(S) FOR AMPLIFICATION PURPOSES, SEE AMPLIFIER, MAGNETIC.


Manufacturer Information:
1096-16-107860BOGUE ELECTRIC MANUFACTURING CO
1096-16-10BXF1BOGUE SYSTEMS INC


Techincal Specification:
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
DC RESISTANCE RATING IN OHMS1.200 SINGLE COMPONENT 3RD CONTROL
DC RESISTANCE RATING IN OHMS120.000 SINGLE COMPONENT 1ST CONTROL
DC RESISTANCE RATING IN OHMS40.000 SINGLE COMPONENT 2ND CONTROL
FREQUENCY RATING60.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
OVERALL HEIGHT6.094 INCHES NOMINAL
OVERALL LENGTH2.987 INCHES NOMINAL
OVERALL WIDTH3.512 INCHES NOMINAL
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SATURATION CURRENT RATING570.0 MILLIAMPERES
WINDING FUNCTION AND QUANTITY2 PRIMARY AND 3 CONTROL SINGLE COMPONENT
WINDING OPERATING VOLTAGE30.00 AC VOLTS MAXIMUM SINGLE COMPONENT ALL PRIMARY
TERMINAL TYPE AND QUANTITY11 SOLDER STUD