5950-00-647-7365 TRANSFORMER,POWER Index 5950-00-647-7371 COIL,TELEPHONE

National Stock Number:
5950-00-647-7368

Federal Supply Class:
5950

National Item Identification Number:
006477368

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
J300T10206003KFT FIRE TRAINER, LLC
P3146-115634MAGNETIKA INC
P3146-180223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC


Techincal Specification:
BODY HEIGHT5.125 INCHES NOMINAL
BODY LENGTH6.250 INCHES NOMINAL
BODY WIDTH5.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH5.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.250 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT2.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE1.23 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT600.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE5.20 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE5.20 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY11 STANDOFF INSULATOR
THREAD SERIES DESIGNATORUNC SINGLE GROUP
THREAD QUANTITY PER INCH20 SINGLE GROUP


Click here to Register for Free 30-day Trial