5950-00-647-7202 TRANSFORMER,POWER Index 5950-00-647-7209 TRANSFORMER,POWER

National Stock Number:
5950-00-647-7204

Federal Supply Class:
5950

National Item Identification Number:
006477204

Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
980494A88601WESTINGHOUSE ELECTRIC CORP MEDIUM POWER TRANSFORMER DIV
M421643-221921RCA CORP DISTRIBUTOR AND SPECIAL PRODUCTS DIV
M421643-249671LOCKHEED MARTIN CORP LOCKHEED MARTIN INFORMATION SYSTEMS AUTOMATED SPARES


Techincal Specification:
BODY HEIGHT8.688 INCHES NOMINAL
BODY LENGTH13.875 INCHES NOMINAL
BODY WIDTH7.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH13.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH6.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESWIRE LEAD TERMINAL HAS PLATE CAP ATTACHED
WINDING FUNCTION AND QUANTITY1 PRIMARY, FIXED AUTOTRANSFORMER TYPE AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT17.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING OPERATING VOLTAGE16.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE2.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY2 STANDOFF, WIRE LEAD AND 6 THREADED STUD


Click here to Register for Free 30-day Trial