5950-00-647-6762 TRANSFORMER,POWER Index 5950-00-647-6764 TRANSFORMER,POWER

National Stock Number:
5950-00-647-6763

Federal Supply Class:
5950

National Item Identification Number:
006476763

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
292-1262-G1A3B150RAYTHEON COMPANY
292-1262-G1A49956RAYTHEON COMPANY
DL292-1262G1-33B150RAYTHEON COMPANY
DL292-1262G1-349956RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT9.000 INCHES MINIMUM AND 9.125 INCHES MAXIMUM
BODY LENGTH7.719 INCHES MINIMUM AND 7.844 INCHES MAXIMUM
BODY WIDTH7.094 INCHES MINIMUM AND 7.219 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH6.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH5.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
OVERALL HEIGHT9.781 INCHES MAXIMUM
OVERALL WIDTH8.593 INCHES MAXIMUM
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.312 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT330.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY1 STANDOFF INSULATOR AND 6 STANDOFF, THREADED STUD
THREAD SERIES DESIGNATORUNC SINGLE GROUP
THREAD QUANTITY PER INCH18 SINGLE GROUP