5950-00-647-5625 TRANSFORMER,POWER Index 5950-00-647-5629 TRANSFORMER,POWER

National Stock Number:
5950-00-647-5627

Federal Supply Class:
5950

National Item Identification Number:
006475627

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
877033ALT506141L3 AVIATION PRODUCTS, INC.
87703706141L3 AVIATION PRODUCTS, INC.


Techincal Specification:
BODY HEIGHT3.125 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
BODY WIDTH2.500 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING60.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM TRANSFORMER POWER RATING25.0 VOLT-AMPERE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY6 SINGLE GROUP
MOUNTING HOLE DIAMETER0.188 INCHES NOMINAL SINGLE GROUP
MOUNTING METHODUNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT100.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING OPERATING CURRENT55.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE45.00 AC VOLTS NOMINAL AND 60.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING6.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY
WINDING POWER RATING6.4 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY
TERMINAL TYPE AND QUANTITY6 SOLDER STUD