5950-00-647-3573 TRANSFORMER,POWER Index 5950-00-647-3579 TRANSFORMER,POWER

National Stock Number:
5950-00-647-3577

Federal Supply Class:
5950

National Item Identification Number:
006473577

Description:
TRANSFORMER,POWER AUTOTRANSFORME

Detail:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.


Manufacturer Information:
292-4262G13B150RAYTHEON COMPANY
292-4262G149956RAYTHEON COMPANY
292-4262G154X10RAYTHEON COMPANY
740495692EDO ARTISAN INC
907290205584AUTODYNE MANUFACTURING CO INC
907290218876U S ARMY AVIATION AND MISSILE COMMAND
HY257429525HYTRONICS CORP.


Techincal Specification:
BODY HEIGHT1.750 INCHES NOMINAL
BODY LENGTH1.312 INCHES NOMINAL
BODY WIDTH1.312 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH0.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY2 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT
WINDING OPERATING CURRENT533.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY OUTPUT
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY INPUT
WINDING OPERATING VOLTAGE15.00 AC VOLTS NOMINAL AND 26.00 AC VOLTS NOMINAL AND 57.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY OUTPUT
TERMINAL TYPE AND QUANTITY5 TURRET
THREAD SERIES DESIGNATORUNC SINGLE GROUP


Click here to Register for Free 30-day Trial