TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
539-100096774HONEYWELL INTERNATIONAL INC.


Techincal Specification:
BODY HEIGHT0.750 INCHES NOMINAL
BODY LENGTH1.000 INCHES NOMINAL
BODY WIDTH0.812 INCHES NOMINAL
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEOPEN
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHODTERMINAL SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESSTART OF SECONDARY 1 CTR TAP OF SECONDARY 2 AND START OF PRIMARY TO BE CONNECTED INTERALLY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT450.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT7.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE26.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE165.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY5 WIRE LEAD