5950-00-646-1222 TRANSFORMER,POWER Index 5950-00-646-1230 COIL,ELECTRICAL

National Stock Number:
5950-00-646-1229

Federal Supply Class:
5950

National Item Identification Number:
006461229

Description:
COIL,ELECTRICAL

Detail:
An item generally consisting of one or more turns of wire or similar conductive material (in special cases it may be considered as a partial turn). It is specifically designed to concentrate magnetic flux generated by the flow of an electric current, to induce in itself an electromotive force, and to add or subtract inductive reactance in a circuit. It may include tuning devices, integral resistors and capacitors; however, excludes FILTER (as modified). For coils wound on resistors which are designed to be inserted into the circuit of a radio frequency stage to suppress high frequency parasitic oscillations, see SUPPRESSOR, PARASITIC..


Manufacturer Information:
126438765054WESTINGHOUSE ELECTRIC CORP POWER GENERATION-GENERATOR DIV
1JH2439PC1E79500WESTINGHOUSE ELECTRIC CORP
1JH2439PC1E89946EATON CORPORATION
315C588G0111660WESTINGHOUSE ELECTRIC CORP CONTROL BUSINESS UNIT
315C588G0189946EATON CORPORATION
37J925SUB11ITEM1E79500WESTINGHOUSE ELECTRIC CORP
37J925SUB11ITEM1E89946EATON CORPORATION
37J976SUB11ITEM1E79500WESTINGHOUSE ELECTRIC CORP
37J976SUB11ITEM1E89946EATON CORPORATION
A-111205584AUTODYNE MANUFACTURING CO INC
AM26LS29DMB54991ASCHBACHER & ASSOCIATES INC
EV-400762110ENERGY VENT INC
S126438779500WESTINGHOUSE ELECTRIC CORP
S126438789946EATON CORPORATION


Techincal Specification:
BODY HEIGHT1.656 INCHES NOMINAL
BODY LENGTH2.594 INCHES NOMINAL
BODY WIDTH2.312 INCHES NOMINAL
DC RESISTANCE RATING IN OHMS60.000 SINGLE COMPONENT SINGLE WINDING
INCLOSURE TYPEFULLY INCLOSED
MOUNTING METHODTERMINAL SINGLE GROUP
RATING METHODWINDING TURNS SINGLE COMPONENT SINGLE WINDING
RELIABILITY INDICATORNOT ESTABLISHED
TURN QUANTITY2000 SINGLE COMPONENT SINGLE WINDING
WINDING CONDUCTOR SIZE0.01420 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE WINDING
WINDING OPERATING VOLTAGE440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE WINDING
WINDING QUANTITY1 SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY2 THREADED STUD