5950-00-535-4633 TRANSFORMER,POWER Index 4140-00-535-4635 FAN,CENTRIFUGAL

National Stock Number:
5950-00-535-4634

Federal Supply Class:
5950

National Item Identification Number:
005354634

Description:
TRANSFORMER,PULSE

Detail:
A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.


Manufacturer Information:
206038028527L3HARRIS TECHNOLOGIES, INC.
363-6009G149956RAYTHEON COMPANY
666062-01212436BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
X-184615634MAGNETIKA INC
X-18461L8V1MAGNETIKA INC
X-184653342OPT INDUSTRIES INC DIV OF ELECTRONIKA INC
X-184680223UNITED TRANSFORMER CORP SUB OF OPT INDUSTRIES INC


Techincal Specification:
MAXIMUM OPERATING TEMP85.0 DEG CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
PULSE REPETITION RATE7.2 KILOHERTZ SINGLE COMPONENT
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY4 STANDOFF, SOLDER LUG
THREAD SERIES DESIGNATORUNC SINGLE GROUP
BODY HEIGHT4.875 INCHES MAXIMUM
BODY LENGTH3.438 INCHES MAXIMUM
BODY WIDTH2.906 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
IMPEDANCE RATING IN OHMS500.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY
IMPEDANCE RATING IN OHMS500.0 NOMINAL SINGLE COMPONENT SINGLE SECONDARY
INCLOSURE TYPEHERMETICALLY SEALED
PRIMARY TO SECONDARY TURN RATIO1 TO 1 SINGLE COMPONENT
PROPRIETARY CHARACTERISTICSPACS