Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
865104-001006481NORTHROP GRUMMAN SYSTEMS CORPORATION
865104-001013973LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
865104-1013973LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
WE 193115634MAGNETIKA INC
WE 193126543WEMS ELECTRONICS TRANSFORMER GROUP


Techincal Specification:
BODY LENGTH1.400 INCHES MAXIMUM
BODY OUTSIDE DIAMETER2.500 INCHES MAXIMUM
FREQUENCY RATING12.5 KILOHERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY1 SINGLE GROUP
MOUNTING METHODCORE AND THREADED HOLE SINGLE GROUP
NOMINAL THREAD SIZE0.164 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING AND SEVEN SECONDARY WINDINGS; SECOND,THIRD,FOURTH,FIFTH,SIXTH,AND SEVENTH SECONDARIES CENTER TAPPED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT123.7 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT21.2 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT212.1 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT989.8 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE127.26 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE17.59 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE43.97 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE9.89 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING0.4 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING POWER RATING1.2 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING1.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING43.5 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE8.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY27 WIRE LEAD
THREAD SERIES DESIGNATORUNC SINGLE GROUP