TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
101-3884-112868BEHLMAN ELECTRONICS, INC
247ASC1976-00130003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
38Z24321811DEK INDUSTRIES INC DIV OF TECHNOLOGY RESEARCH INC
4216722558COAST/ADVANCED CHIP MAGNETICS, INC.
A1097905584AUTODYNE MANUFACTURING CO INC
C1600872149ELECTRONIC TRANSFORMER CORP


Techincal Specification:
BODY HEIGHT1.615 INCHES MINIMUM AND 1.635 INCHES MAXIMUM
BODY LENGTH3.240 INCHES MINIMUM AND 3.260 INCHES MAXIMUM
BODY WIDTH3.427 INCHES MINIMUM AND 3.447 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.115 INCHES MINIMUM AND 1.135 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.138 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING VOLTAGE0.052 AC VOLTS NOMINAL AND 0.104 AC VOLTS NOMINAL AND 0.156 AC VOLTS NOMINAL AND 0.208 AC VOLTS NOMINAL AND 0.259 AC VOLTS NOMINAL AND 0.311 AC VOLTS NOMINAL AND 0.363 AC VOLTS NOMINAL AND 0.418 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE0.467 AC VOLTS NOMINAL AND 3.63 AC VOLTS NOMINAL AND 4.15 AC VOLTS NOMINAL AND 4.67 AC VOLTS NOMINAL AND 5.19 AC VOLTS NOMINAL AND 5.40 AC VOLTS NOMINAL AND 6.22 AC VOLTS NOMINAL AND 6.75 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE7.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY21 TURRET
THREAD SERIES DESIGNATORUNC SINGLE GROUP