5996-00-140-8153 AMPLIFIER SUBASSEMBLY Index 5995-00-140-8162 LEAD,ELECTRICAL

National Stock Number:
5950-00-140-8156

Federal Supply Class:
5950

National Item Identification Number:
001408156

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
160007-113058SORA POWER INC.
160007-120950ESPEY MFG AND ELECTRONICS CORP
160007-124930L3HARRIS TECHNOLOGIES, INC


Techincal Specification:
DISTANCE BETWEEN MOUNTING FACILITY CENTERS7.970 INCHES MINIMUM AND 8.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS
FREQUENCY RATING380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPTHREE PHASE TO THREE PHASE SINGLE COMPONENT
OVERALL HEIGHT7.030 INCHES MAXIMUM
OVERALL LENGTH8.970 INCHES MINIMUM AND 9.030 INCHES MAXIMUM
OVERALL WIDTH7.970 INCHES MINIMUM AND 8.030 INCHES MAXIMUM
MAXIMUM OPERATING TEMP130.0 CELSIUS
MOUNTING FACILITY QUANTITY3 ALL GROUPINGS
MOUNTING HOLE DIAMETER0.358 INCHES MINIMUM AND 0.366 INCHES MAXIMUM ALL GROUPINGS
MOUNTING METHODUNTHREADED HOLE ALL GROUPINGS
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.25 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE1.70 AC KILOVOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING POWER RATING2.125 KILOVOLT-AMPERES SINGLE COMPONENT ALL SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD BROUGHT OUT TO TERMINAL AND CORE GROUNDED TO SECONDARY TERMINAL SINGLE COMPONENT
TERMINAL TYPE AND QUANTITY17 STANDOFF, THREADED STUD