5950-00-139-9700 TRANSFORMER,POWER Index 5905-00-139-9702 RESISTOR,VARIABLE,WIRE WOUND,NONPRECISIO

National Stock Number:
5950-00-139-9701

Federal Supply Class:
5950

National Item Identification Number:
001399701

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
40167412909CARDION INC
40167420284AIMTRON SYSTEMS, LLC
869A172149ELECTRONIC TRANSFORMER CORP


Techincal Specification:
BODY HEIGHT2.730 INCHES MINIMUM AND 2.750 INCHES MAXIMUM
BODY LENGTH3.050 INCHES MINIMUM AND 3.070 INCHES MAXIMUM
BODY WIDTH2.550 INCHES MINIMUM AND 2.570 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING45.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODTHREADED STUD SINGLE GROUP
NOMINAL THREAD SIZE0.190 INCHES SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT1.8 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING CURRENT800.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE105.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE18.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE18.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE8.50 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
TERMINAL TYPE AND QUANTITY15 TAB, SOLDER LUG
THREAD SERIES DESIGNATORUNF SINGLE GROUP