DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 2.130 INCHES MAXIMUM |
OVERALL LENGTH | 1.730 INCHES MAXIMUM |
OVERALL WIDTH | 1.310 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 15 PIN ALL FUNCTIONS |
TIME DELAY | 0.025 SECONDS MAXIMUM FIXED RELEASE TIME |
TIME DELAY | 1.70 SECONDS MAXIMUM FIXED OPERATE TIME |